XSCH series of single-input channel digital intelligent instrument

(Suitable for all types of analog output with the combined use of sensors)
The basic error :± 0.2% F S,
Measuring cycle 0.2 s
Showing :1999 ~ 9999
Input :voltage, current, thermal resistance, thermocouple, mV, Potentiometers, resistors
Pressure gauge, and other types of signals
Power supply: 220 V AC, 24V DC or 12 V DC
2 points alarm: relay output
Trnsmissing the singal of sensor to standard current (4-20mA)
Supply the power(24VDC) for the sensor.
Specifications: 160 × 80,96 × 96,96 × 48,72 x 72, etc.
XST Series single-input channel digital intelligent instrument

(Suitable for all types of analog output with the combined use of sensors)
The basic error :± 0.2% F S,
Measuring cycle 0.2 s
Showing :1999 ~ 9999
Input :voltage, current, thermal resistance, thermocouple, mV, Potentiometers, resistors
Pressure gauge, and other types of signals
With 8 broken line to improve system accuracy
supply Power :220 V AC, 24V DC or 12 V DC
8 points alarm: relay output
Transmissing the singal of sensor to standard current (4-20mA),and Communications ,Print Records
Supply the power(24VDC) for the sensor.
Specifications: 160 × 80,96 × 96,96 × 48,72 x 72, etc.
XSC series PID controller

(For temperature, pressure, liquid level, flow control value set)
manual / automatic control output
Applicable to thermal resistance, thermocouple, voltage, current, remote pressure gauge
The basic error :± 0.2% F S, measuring cycle 0.2 s, showing :1999 ~ 9999
Self-tuning function, the positive and negative effects, control cycle, output limiter can be set
Control output forms: continuous PID DC current, voltage output or switchs PID
Power supply:220 V AC, or 24V DC
3 points alarm Transmitter output communications,
Specifications: 160 × 80,96 × 96,96 × 48,72 x 72, etc.
Dual-display
XSJ-Series Flow Totalizer

(Applicable to liquid, the cumulative gas volume flow measurement and control)
Basic error :± 0.2% F S, 16 A / D converters, measuring cycle 0.2 s
Applicable to the flow sensor with current, voltage, pulse output,
Option of transient Flow by the hour or minutes for the measurement units.
Small-signal resection, prescribing, digital filtering, adjustable function
Input signal with 8 broken line to improve system accuracy ,and reduce the nonlinear error of the sensor.
Blackout Records function can record total blackout time, the number of blackouts and the last eight times a power blackout and the real-time time. View form the panels.
Single-show type: The cumulative amount of instantaneous flow switching shows
Dual-display-independent display
2 points alarm output for instantaneous flow,
Cumulant output with pulse
Power supply:220V AC or 24 V DC, 12V DC
Transmission output
Communication and Print
Specifications :160 × 80,96× 96,96 × 48
XSD series multi-channel digital instrument

(Especially suitable for multi-channel calculation with Adder or Subtraction or Comparison)
Multi-channel display and measurement,lower equipment costs
2-channel, 3-channel, 4-channel three types.
XSD Series is similar to XST Series with the basic functions (but 8 broken line amendment)
The model and range of input signal in each channel can be set independently.
Adjust and digital filtering in each channel can be done so.
Power supply :220 V AC, 24V DC or 12 V DC
8 points alarm
transmission output
communication and print signal ,recorder
Supply power for sensor (transmitter)
Specifications 160 × 80
XSSG 8-channel flash Alarm

Input: 8 pathway switching voltage tap or relay switching
output: 1 relay output,
contact capacity of 250 V, 2A (resistive load)
silencers: external manual, panels manual, automatic mode
Testing: external contact panel buttons or switches activated *
Communication Interface: RS232, RS485
Power supply: 24 V DC, 12V DC, etc.
Specifications 160 × 80
JS series timer

The minimum time unit 0.01 seconds
The longest time-9999 hours and 59 minutes and 59 seconds
4 digials or 8 digials display mode
Power-fail to maintain function,
Power-fail to stop at the time, but the time value is not lost
2 points preset output, When reached preset , the signal output corresponding taps
3 points switching input, respectively, for the start, stop and reset control
Communication Interface
Four kinds time mode can be set up:
① Power-on automatically start to time
② Start button or trigger input
③ activated trigger input closure
④ start, stop with control buttons, ""
|