Soft electrode Hard electrode auxiliary transmission unit E/F
The sense 2060 is an advanced, state-of-the-art, two-wire, Capacitance-based level transmitter suitable for a wide range of process applications. This level measurement solution is suitable for both high temperature and causticity liquids/solids. The level gauge system consists of an explosion proof housing, field-replaceable electronics module, and level measurement probe/sensor. Common industrial scurviness applications include the measurement of liquid hydrogen, liquid oxygen, solid powder, acid,oil/water interface and others. The latest in microprocessor technology allows the level transmitter to consistently and reliably measure the level of your process fluid.
Simple Calibration
In contrast to competitor's systems in the industrial applications market, the Model SENSE2060 level gauge provides simple microprocessor-controlled calibration. Simply turn the tedious potentiometer adjustments are required for calibration to set the zero and span for any installed sensor.
Remote monitoring
The Sense2060 level gauge comes with a 4-20 mA output which corresponds to 0-100% level. A range of simple and reliable Liquid / Solid Level Transmitters which includes Immersion type Transmitter (for liquid) as well as RF Capacitance type Level Transmitter (for liquids / solids) are available. Options of SS, PP and PTFE wetted parts having max. range up to 15 Mtr.s, Max. temp. of 200℃ and Max. pressure of 60 Kg/cm2 to suit various industrial applications. Options of Current or Voltage Transmission outputs are available. Indicating controllers are available with panel / wall mounted enclosures and option of 1 to 4 set points. Enclosure options of Weather proof IP 65 / IP56 as well as Ex - proof enclosures suitable to hazardous areas Gr. IIA, IIB and IIC.
Application Accurate and continuous level indication / transmission / control of liquid and solid levels in various industries like Chemical, Fertilizer, Petroleum and Petro - Chemicals, Veg - Oil refineries, Power generation, Pharmaceuticals, Automobiles, Cement and Metal industries.
Application of Principle
The level measurement of a medium in a tank, is accomplished by taking advantage of the capacitance theory. The tank wall, the probe and the medium are all capacitors. A high frequency sine wave is then applied between the probe and the tank wall. The level change of the medium will consequently change the current of the applied sine wave. From the formula Z=1/(2pfc), we know that if the capacitance increases, the impedance gets smaller and the current gets bigger. If the capacitance decreases, the impedance gets bigger and the current gets smaller. When the small current change is amplified and sent to a MG series meter, the output signal is 0/4-20mA or 0-10VDC.
Can be applied at high-temperature, acid & alkali and various style of tank or equipment, will not be affected by Steam, Sound wave, Pressure, Temperature.
Operating voltage: 24VDC; max. output current: 20mA, resolution: 0.2% .Probe material includes steel, stainless steel, PVDF coated, PP coated, or PFA coated.Max. tensile strength of cable probe can up to 50M in length.
Sensitive range: 150pf, 500pf, 1500pf
Max. operating temperature: 200℃,Enclosure protection IP-65 or explosion-proof.
Wires:

transmission unit introduced
simulation output quantity and range of zero can be arbitrarily set.
When the broken resistance, breaking even, interrupted occur ,it will show suggested with a flicker
Instrument power off state, parameters can be set up to maintain permanent
Technical parameters
Accuracy: the four-digit significant: 0.5% Fs ± a digital or 0.2% Fs ± a digital transmission output: 0.5% Fs;
Input signals: Sensor provided
Output: 4 to 20 mA, 0 ~ 20mA, 0-10mA, 0 - 5V, 1 - 5V, 0 to 10V;
Power supply: 85 ~ 265 VAC (50Hz ± 2Hz), or 24 VDC ± 2V;
The main safety indicators
High electronic valtage - shell (land side):> 100 Mohms, 1500 V ,1 minutes, with no breakdown fly arc.
Common to - shell (land side):> 10 Mohms, 500 V, 1 minutes, with no breakdown fly arc.
Working conditions
Temperature: -20 ~ 50 ° C, relative humidity: <85% RH, no-corrosive gases.
Transmission unit model table
|
E-
F- |
□ □□□□□□□ |
Introduction |
|
Series |
1 |
|
Show in digital |
|
Loop |
10
T0 |
|
Single signal
Special |
|
Input type |
T0
|
|
Input :Sensor provided
|
|
Output
type |
B1
B2
B3
B4
B5
B6
B7 |
|
Output:0~10mA
Output:4~20mADC
Output :1~5VDC
2 outputs:4~20mADC
2 outputs:4~20mADC and 1~5VDC
2 output: 4~20mADC and 4~20mADC
2 output :1~5VDC |
|
Power
supply |
D
A |
24VDC
80~220VAC |
|
|
|
|
|
|
|
Selection method
|
Models |
Process
connections |
pressure |
Temperat-ure |
Electrode
type |
Electrode length |
Measured length |
Measured material |
|
Sense2060E
Stand-ards guide-way
Size:
|
F25/50:
Dn25/
Dn 50
flange |
N:
Atmospheric pressure |
A:
-30~80℃ |
T1:
Hard electrode |
Length number
In cm |
Length number
In cm |
W:
water |
|
D:
<6
Mpa |
B:
80~150
℃ |
T2:
auxiliary |
O:
oil |
|
R1:
M27*2 |
T4:
Soft
electrode |
S:
With
steam |
|
Sense2060F
Stand-ards guide-way
Size: |
R2:
G1' |
T:
special |
T:
special |
T:
special |
P:
Solid
powder |
|
R3:
G3/2' |
T:
special |
|
Sense
2060E |
R1 |
N |
A |
T1 |
160 |
150 |
w |
For example Selection:transmission unit is E model
Sense2060E-R1-N-A-T1-160-150-W
Explanation:sense2060 RF level transmitter,
Process connections:M27*2,Pressure:atmospheric pressure
Temperature range:-30~80℃,hard electrode,electrode length:1.6m,measured length:1.5m,measured water level.
|