Sense WFD Series electromagnetic flowmeter
2007-12-3 10:14:13
 

Outlined

Electromagnetic flowmeter is an application of Faraday's law of electromagnetic induction flowmeters by lining its main sensor measurement of the insulation material, through the wall of the installation of a working electrode, and to produce a magnetic field coil and the core components.When the conductivity of the fluid flow sensor, the sensor electrode and will produce an average fluid velocity is proportional to the voltage signal. The signal amplification by converters, directly reflect the cumulative flow and transient flow and can output analog and digital signals.Electromagnetic flowmeter can be used to measure conductivity of liquid pipeline closed and the volume of slurry flow, applied to the chemical industry, electric power, metallurgy, mining, water supply and drainage, paper, pharmaceuticals, food and other industries.

 

The main technical parameters and function

Instrument main function

 

A;Flow measurement function; The instantaneous flow measurement, cumulative flow, velocity and at the same time .

B; tracking; In fluid flow zero, tracking, automatic zero adjustment

C;Cut off the flow of small function; Before moving flows can be set value, or resection of the small flow mutation      interference suppression

D;Pros flow indicator; Forward flow, the flow of instructions for the "+" reverse flow, the instructions "-."

E;Damping function;0-99 seconds of the time set damping, the average of the  instantaneous flow measurement. 

F;ATC alarm function; When the ATC pipeline, the police are given instructions, the cumulative stop.

G;Upper and Lower alarm function; The instantaneous flow can be set upper and lower limits,when flow overruns, the police are given instructions and alarm signal output.

H;Signal output function; 4-20mA output, output value and should be relatively instantaneous flow, the corresponding range adjustable.

I;Calibration function; Instrument calibration sub can further enhance the linear meters,  expanding the scope of measurement, the measurement accuracy.

J;Set password function; Passwords can be set to prevent arbitrary operation.

K;Environmental conditions; Temperature: -10 ¡ã C -60 ¡ã C relative humidity of 5% -90%

L;Working conditions;

   Somatotype: 70 ¡ã C

   Separated :Poly PTFE lining --- 120 ¡ã C, poly chloroprene rubber lining ---80 ¡æ,

   polyurethane lining --80 ¡æ,  polypropylene liner --- 120 ¡æ.

   Fluid conductivity: not less than 5us/cm

M;frame;  Flange type: 4.0Mpa (DN10 - DN150) 1.6Mpa (DN10-converter )

   Facing folder: 4.0Mpa (DN10 - DN150) 1.6Mpa (DN10-converter)

N;Power; Single-phase AC 85V - 265V, 45Hz - 450Hz ,18V - 36V DC

 

 Technical parameters

The implementation of standards; JB/T9248-1999 electromagnetic flowmeter

Basic parameters and performance indicators 

---- Nominal diameter: 10,15,20,25,32,40,50,65,80,100,125,150,200,250,300,350,400,450, 500,600,700,800 ,   900,1000 ---- Corresponding velocity of the flow range: 0-1.5 m / s to 0-12 m / s 

---- Accuracy: ¡À 0.5% (indication)

--- Measurement of materials: stainless steel 1Cr18Ni9Ti

---- Lining materials: Teflon, polyethylene chloroprene rubber, polyurethane, polypropylene 

---- Electrode materials: stainless steel 0Cr18Ni12Mo2Ti, Harrington alloy B, C Harrington alloys,  titanium, platinum according alloy, stainless steel coated tungsten carbide. 

---- Flange materials: carbon steel, stainless steel.

---- Protective shell: IP65/68

---- Explosion levels: Exia II Skilling

---- SPLIT Sensor and converter spacing ¡Ü 100M 

---- Power loss: <20W

---- Time constant-99 seconds:

---- Resection of the small signal:-49%

---- Input impedance: 1015 Ohm, a simulation system than 110db, the school  system can automatically spot "0"

---- Luxury-20mA current output ¡À 0.01mA

 -- Load-750 ohm resistor: 

 ---- Frequency output: maximum output frequency or optional 1KHz kHz, with the photoelectric isolation transistor collector on the next 20K ohm resistor output, high-output voltage: nationally RL = 24V x / (RL +20 K ohms), VL = 0V,  error <1Hz , the external power supply is not greater than 35V, or internal segregation +24 V power supply.

---- Pulse output: the accumulated output of pulses, with photoelectric isolation transistors open collector output, an external power supply is not greater than 35V,or internal segregation +24 V power supply, high-voltage output ibid., nationally VL Ibid.

---- Threshold of total output: 0.001 million cubic meters -1000 cubic meters can be located. 

 ---- Output level: nationally VL = +5 V = 0V 

 ---- Serial output: standard RS485 serial interface

 -- Anti-jamming: electromagnetic compatibility and anti-jamming performance is better than the international standard 3

---- Electrical isolation: analog input and analog output voltage Insulation> 500V, analog  input and AC power Insulation> 1500V, and the analog output voltage insulation between the earth> 500V, and the analog output AC power Insulation> 1500V, pulse output voltage  and earth Insulation > 500V, pulse output and AC power Insulation> 1500V.

Appearance size

Table 1

Nominal diameter

A

B

C

Reference weight

10

200

60

284

10

15

200

60

294

12

20

200

60

307

14

25

200

60

312

16

32

200

75

334

17

40

200

75

352

19

50

200

100

368

22

65

200

100

382

25

80

200

100

400

29

100

250

135

430

31

125

250

135

460

37

150

300

150

483

41

200

350

180

545

45

250

450

210

603

50

300

500

240

653

60

350

550

310

713

145

400

600

390

773

180

450

600

390

823

215

500

600

390

875

245

600

600

390

985

335

700

700

470

1098

435

800

800

550

1217

545

900

900

640

1317

655

1000

1000

710

1425

810

 

 

 

 Parametric Selection

Sense-WFD¡ª¡õ¡õ£­¡õ£­¡õ£­¡õ£­¡õ£­¡õ£­¡õ£­¡õ£­¡õ£­¡õ

                 A    B  C   D   E   F  G   H   I   J

A----Nominal Diameter  DN£¨mm£©

 

code

DN

code

DN

code

DN

11

10

27

80

43

400

13

15

29

100

45

450

15

20

31

125

47

500

17

25

33

150

49

600

19

32

35

200

51

700

21

40

37

250

53

800

23

50

39

300

55

900

25

65

41

350

57

1000

 

B----pressure £¨Mpa£©

06¡ª0.6£¨DN10£­DN1000£©

10¡ª1.0£¨DN10£­DN1000£©

16¡ª1.6£¨DN10£­DN600 £©

40¡ª4.0£¨DN10£­DN150 £©

C----Lining Materials

1-Polytetrafluoroethylene (F4) (DN10-DN1000)

2-Poly chloroprene rubber (DN10-DN1000)

3-Polyurethane (DN15-DN1000)

4-Polypropylene (DN10-DN1000)

D----Electrode Material

1 stainless steel 0Cr18Ni12MoTi

2 Harrington alloy B

3 Harrington alloy C

4 Titanium

5 Pt / Ir alloys

6 tantalum alloy

7 stainless steel tungsten carbide coating

 

E----Sensor protection rating

 

1  IP65

2         IP68

 

F----Explosion levels

0 no

1 md¢òBT4£¨somatotype IP65£¬DN10£­DN600£©

2 md¢òBT4£¨Separated IP65£¬DN10£­DN1000£©

3 md¢òBT4£¨Separated IP65£¬Converters in the security zone DN10£­DN600£©

 

 G -- Annex

        0 No

        1 flange Grounding

 H - Structure

        1  Separated

        2  somatotype

I - Power

1 85--265VAC   45--50Hz

2 18-36VDC

J ---- converter form

1  the keys

2  infrared remote -

 
Download£º
     Sense WFD Series electromagnetic flowmeter.pdf
 